TS-E24mm f/3.5L
TS-E45mm f/2.8
TS-E90mm f/2.8
ENG
Instructions
a Safety Precautions
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Do not make any changes or modifications to the equipment
unless otherwise specified in the instructions. If such changes or
modifications should be made, you could be required to stop
operation of the equipment.
This equipment has been tested and found to comply with the
limits for a class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
againharmful interference in a residential installation. This
uipmnt generates, uses and can radiate radio frequency
nergy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
a Safety Precautions
●
Do not look at the sun or a bright light source
through the lens or camera. Doing so could result in
loss of vision. Looking at the sun directly through the
lens is especially hazardous.
●
Whether it is attached to the camera or not, do not
leave the lens under the sun without the lens cap
attached. This is to prevent the lens from concentrating
the sun’s rays, which could cause a fire.
Handling Cautions
● If the lens is taken from a cold environment into a
warm one, condensation may develop on the lens
surface and internal parts. To prevent condensation
in this case, first put the lens into an airtight plastic bag
before taking it from a cold to warm environment. Then
take out the lens after it has warmed gradually. Do the
same when taking the lens from a warm environment
into a cold one.
● Do not leave the lens in excessive heat such as in a
car in direct sunlight. High temperatures can cause
the lens to malfunction.
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Consult the dealer or an experienced radio/TV technician for
help.
This Class B digital apparatus complies with Canadian ICES-003.
ENG-2
Nomenclature
Tilt scale (→ 7)
Infrared index (→ 11)
Distance index
Distance scale (→ 5, 11)
Tilt index
Depth-of-Field scale (→ 11)
Lens mount index (→ 5)
Tilt knob (→ 7)
Contacts
Shift knob (→ 9)
Shift index
Shift scale (→ 9)
For detailed information, reference page numbers are provided in parentheses (→ **).
ENG-3
Nomenclature
Tilt index
Tilt lock knob (→ 7)
Tilt scale (→ 7)
Focusing ring (→ 5)
Hood mount (→ 13)
Shift index
Rotation lock release button
(→ 10)
Lens
Shift scale (→ 9)
Shift lock knob (→ 9)
Filter mounting thread
(→ 14)
For detailed information, reference page numbers are provided in parentheses (→ **).
ENG-4
1. Mounting and Detaching the Lens 2. Focusing
See your camera’s instructions for details on
mounting and detaching the lens.
● When mounting or detaching the lens, always
ensure that the tilt and shift scales are set to the
“0” position.
● After detaching the lens, place the lens with the
rear end up to prevent the lens surface and
contacts from getting scratched.
● If the contacts get soiled, scratched, or have
Focus a TS-E lens by turning the focusing ring.
(Shos cannot be taken using the auto focus.)
fingerprints on them, corrosion or faulty
connections can result. The camera and lens
may not operate properly.
● If the contacts get soiled or have fingerprints on
them, clean them with a soft cloth.
● If you remove the lens, cover it with the dust
cap. To attach it properly, align the lens mount
index and the ꢀ index of the dust cap, and turn
clockwise. To remove it, reverse the order.
● After using tilt or shift, readjust the focus.
● The distance scale is only valid when the tilt
scale is set to the “0” position.
ENG-5
3. Tilt Function
Tilting inclines the lens relative to the image plane. When the tilt scale is set to the “0” position, the
focusing and imaging planes are parallel. However, tilting puts the focusing plane at an angle to the
imaging plane.
● Example 1
● Example 2
To shoot so that all of an extensive subject is in focus, you must normally use a small aperture to
obtain a large depth of field. But tilting allows you to keep all of the subject in focus even when there
is insufficient depth of field (Example 1). Or, by tilting in the opposite direction, you can focus on a
specific part of the subject (Example 2).
ENG-6
Using Tilt
Loosen the tilt lock knob by
turning it in the direction of
the arrow.
Turn the tilt knob to adjust
the amount of tilt. Focus the
shot by turning e focusing
ring.
Turn the tilt lock knob in the
direction of the arrow to lock
the amount of tilt for the
shot.
● When you tilt the lens, sharp portions of the tilt mechanism are exposed and care should be taken to avoid
touching these portions.
● If you use the tilt and shift functions on the TS-E24mm f/3.5L at the same time, only use them within the
area of the light-gray tilt scale settings. Tilting the lens to other settings may cause vignetting.
However, if the tilt function is used alone, none of the tilt scale settings cause vignetting.
ENG-7
4. Shift Function
Shifting moves the optical axis of the lens in parallel off the center of the imaging plane.
Shift can be used to good effect in the situations shown below.
● If you photograph a subject such as a
building with a normal lens, the top of
the building tapers away. But by placing
the camera parallel to the building and
shifting the lens, you can correct this
tapering effect.
● When you are shooting a reflective
subject, you can move the camera to a
position where the camera does not
appear in the shot and then use shift to
take the picture. This lets you keep the
camera out of the shot without having
to change the shot composition.
ENG-8
Using Shift
Loosen the shift lock knob
by turning it in the direction
of the arrow.
Turn the shift knob to adjust
the amount of shift. Focus
the shot by turg the
focusing r
Turn the shift lock knob in
the direction of the arrow to
lock the amount of shift for
the shot.
● When you shift the lens, sharp portions of the shift mechanism are exposed and care should be taken to
avoid touching these portions.
● If you use the tilt and shift functions on the TS-E24mm f/3.5L at the same time, only use them within the
area of the light-gray shift scale settings. Shifting the lens to other settings may cause vignetting.
With large amounts of shift, the amounts of peripheral light at the top and bottom or left and right sides of the
screen may differ, so shooting with a small aperture is recommended.
ENG-9
5. Rotation
The rotation function enables you to change the direction of tilt or
shift by rotating the tilt-shift mechanism.
With the lens mounted on the camera, push the rotation lock release
button towards the mount and then turn the tilt-shift mechanism.
● The mechanism can be rotated through 90°. The lens clicks every 30° and
locks in place in the 90° position.
● When rotating the lens, set the tilt and shift scales to the “0” position.
● Note that rotating the tilt-shift mechanism quickly while pressing on the
rotation lock release button may cause the shift lock knob to strike your
fingers.
ENG-10
6. Depth-of-Field Scale
(TS-E24mm f/3.5L)
7. Infrared Index
(TS-E24mm f/3.5L)
The depth of field is the distance in front of and
behind the plane of focus on the subject that
appears sharp. The depth of field is indicated by
the area between the depth-of-field scale lines
below the distance scale. The numbers on the
scale are F values, and for example, if the
shooting distance is 1.5 m and the aperture is
f/8, the area in focus will extend from about 1 m
to 3 m.
he infrared index corrects the focus setting
when using monochrome infrared film. Focus on
the subject in MF, then adjust the distance
setting by moving the focusing ring to the
corresponding infrared index mark.
Some EOS cameras cannot use infrared film. See
the instructions for your EOS camera.
● The infrared index position is based on a
wavelength of 800 nm.
● Be sure to observe the manufacturer’s
instructions when using infrared film.
● Use a red filter also when you take the picture.
● The depth-of-field scale is only valid when the
tilt scale is set to the “0” position.
● The depth-of-field scale is an approximate
indicator.
ENG-11
8. TS-E Tripod Adapter
(Sold Separately)
9. Exposure
With some camera models, the tilt, shift and
rotation functions can no longer be used when
the camera is mounted directly on a tripod.
When this happens, fit the optional TS-E tripod
adapter into the tripod mount socket on the
camera before mounting the camera on the
tripod.
Shots can be taken using AE (automatic
exposure) as long as the tilt and shift scales are
set to the “0” position.
The use of AE is not recommended when the
lens is tilted or shifted as exposure errors may
result. It is recommended that you use the
exposure values when the tilt and shift scales
are set to the “0” position as a guide and then
take the shot with as many exposure settings as
possble.
ENG-12
10. Hoods
The EW-75B II, EW-79B II and ES-65 III lens hoods can keep unwanted light out of the lens, and
also protects the lens from rain, snow, and dust.
Attach the hood using the following procedure.
TS-E24mm f/3.5L
Turn the hood in the direction of the arrow to attach it
securely.
TS-E45mm f/2.8 • TS-E90mm f/2.8
1
1) Pressing the buttons on the base of the hood inwards,
push the hood onto the hood mount on the lens.
2) Release the buttons so that the catches on the hood fit
into the grooves on the mount.
2
1
ENG-13
Hoods
11. Filters
(Sold Separately)
You can attach filters to the filter mounting
thread on the front of the lens.
● Part of the picture may be blocked if the hood is
not attached properly.
● When attaching or detaching the hood, grasp
the base of the hood to turn it. To prevent
deformation, do not grasp the rim of the hood to
turn it.
● Only one filter may be attached.
● Use a polarizing Canon filter.
● To adjust the polarizing filter, first remove the
lens hood.
The hood can be reverse-mounted on the lens for
storage.
ENG-14
12. Extension Tubes
13. Close-up Lenses
(Sold Separately)
(Sold Separately)
You can attach extension tube EF12 II or EF25
II for magnified shots. The shooting distance
and magnification are shown below.
Attaching a 250D or 500D close-up lens enables
close-up photography. Compatibility with close-
up lenses is as follows.
TS-E24mm f/3.5L
• 250D: Cannot be used
• 500D (72mm): 0.19 to 0.05×
TS-E24mm f/3.5L
Focusing Distance
Magnification (×)
Range (mm)
Close
Long
Close
Long
TS-E45mm f/2.8
• 250D: Cannot be used
00D (72mm): 0.25 to 0.09×
distance distance distance distance
EF12 II
EF25 II
171
166
179
167
0.62
1.21
0.49
1.10
TS-E90mm f/2.8
• 250D (58mm): 0.69 to 0.36×
• 500D (58mm): 0.49 to 0.18×
TS-E45mm f/2.8
Focusing Distance
Range (mm)
Close
Magnification (×)
Close Long
Long
distance distance distance distance
239 299 0.44 0.27
Cannot be used
EF12 II
EF25 II
TS-E90mm f/2.8
Focusing Distance
Range (mm)
Close Long
distance distance distance distance
Magnification (×)
Close Long
EF12 II
EF25 II
415
373
817
486
0.43
0.60
0.14
0.31
ENG-15
Specifications
TS-E24mm f/3.5L
24mm f/3.5
Lens Construction 9 groups, 11 elements
TS-E45mm f/2.8
45mm f/2.8
9 groups, 10 elements
TS-E90mm f/2.8
90mm f/2.8
5 groups, 6 elements
f/32
Focal Length/Aperture
Minimum Aperture
f/22
84°
53°
f/22
51°
30°
Diagonal
Angle of View
Vertical
27°
15° 11’
22° 37’
(Normal)
Horizontal
74°
44°
Min. Focusing Distance
Max. Magnification
0.3m (1.0ft.)
0.14×
0.4m (1.3ft.)
0.16×
0.5m (1.6ft.)
0.29×
173 × 263mm
(6.8 × 10.4inch)
150 × 226mm
(5.9 × 8.9inch)
8°
82 × 123mm
(3.2 × 4.8inch)
Field of View
Tilt amount
Shift amount
11mm
Each degree from 0 to
6° (light gray),
7° and 8° (red)
Each mm from 0 to
7mm (light gray),
8 to 11mm (red)
Tilt scale display
Each degree from 0 to 8° (light gray)
Each mm from 0 to 11mm (light gray)
Shift scale display
Rotation mechanism
Locks at –90°, 0° and +90°, clicks every 30°
ENG-16
Specifications
Filter Diameter
TS-E24mm f/3.5L
TS-E45mm f/2.8
TS-E90mm f/2.8
72mm
58mm
Max. Diameter and Length 78 × 86.7mm (3.1 × 3.4inch) 81 × 90.1mm (3.2 × 3.5inch) 73.6 × 88mm (2.9 × 3.5inch)
Weight
Hood
Lens Cap
Case
570g (18.4oz)
EW-75B II
645g (20.8oz)
EW-79B II
565g (18.2oz)
ES-65 III
E-58
E-72
LP1216
LP1016
● The lens length is measured from the mount surface to the front end of the lens. Add 21.5 mm
when including the lens cap and dust cap.
● The size and weight listed are for the lens only, excepas indicated.
● The EF1.4× II/EF2× II extenders cannot be used th the lenses listed above.
● Aperture settings are specified on the camer
● All data listed is measured according to Canon standards.
● Product specifications and appearance are subject to change without notice.
ENG-17
Download from Www.Somanual©s.CcAoNmO.NAINllCM. 1a99n1uals Search And Download.
CT1-7544-006
2009.7
|